| Restocking Fee | No |
|---|---|
| Return shipping will be paid by | Seller |
| All returns accepted | Returns Accepted |
| Item must be returned within | 30 Days |
| Refund will be given as | Money back or replacement (buyer's choice) |
| Screen | Touchable |
| VCG Acquisition & Analysis | Yes |
| UPC | Does not apply |
| Rhythm Mode | Up to 300 seconds of R-R analysis in 1 or 3 rhythms lead |
| MPN | Does Not Apply |
| Channels | 12 |
| Brand | Biocare |
| Full Keyboard | Yes |
| Number of Leads | 12 |
| EAN | Does not apply |
| Number of Channels | 12 |
| Labels & Certifications | FDA 510K Compliant |
| Lead Mode | Standard 12 leads, Cabrera, Nehb |
| Analysis Report | Simple report + Detailed measurement data report |
| ECG & EKG Machine Type | Electrocardiograph |
| Thermal Paper | Z-fold paper: 210 mm * 140 mm-140p |
| Display | 9 inches |
| PATIENT TYPE | Adults & Pediatrics |
Check the listing for details. 12 channel ECG Machine with interpretation for advisory diagnosis FDA approved. Condition: New. Listed at 1499.00 USD. 12 Channel ECG Sheet:View and print in 12 channels, highly effcient 9-Inch Touch Screen :High resolution color touchscreen with handwriting Adults & Pediatrics:Support ECG tests for both adults & children Auto-analysed Result:12-lead ECG with interpretation for advisory diagnosis. VCG Acquisition:Provide advanced analysis of Vectorcardiography Compact & Portable:Built-in handle, easy to carry Multiple file options:Multiple ports and formats for ECG data transmission ♥ 12-LEAD SIMULTANEOUS ACQUISITION:The ECG machine is able to simultaneously process 12 leads of ECG signals with automatically interpretation. Its user-friendly design ensures easy operation and freedom of built-in ECG parameters measurement and interpretation. 12-LEAD ♥ ♥ ♥ ♥ SIMULTANEOUS ACQUISITION:The ECG machine is able to simultaneously process 12 leads of ECG signals with automatically interpretation. Its user-friendly design ensures easy operation and freedom of built-in ECG parameters measurement and interpretation. ♥ HIGH-RESOLUTION TOUCHSCREEN WITH HANDWRITING FUNCTION:The 9-inch TFT-LCD display with a 15-degree angle is clear to read every detail of 12-lead ECG signals. Its touchable screen makes the operating system faster, saving time for cardiologists, physicians, or EMS staff.♥ PRINT 12-CHANNEL ECG WAVEFORMS IN SECONDS:Adjustable printing speed from 5mm/s to 50mm/s. Various formats for printing: 3×4, 3×4+R, 3×4+3R, 6×2, 6×2+R, 6×2+3R, 12, 12+R, 12+3R. All waveforms and analysis results are printed on large size of thermal paper (210 mm×140 mm), making it easy for doctors to take instant ECG tests and compare.♥ BUILT-IN HANDLE FOR REMOTE 12-LEAD ECG TESTS:Biocare iE12A portable EKG machine weighs about 3.4kg (7.5lbs). With its built-in handle, the unit is easy to carry to anywhere the patient need the most. Perfect choice for ambulance or such emergency medical services.♥ SHORTCUT KEYS MAKE EFFICIENT CLINICAL OPERATIONS:The unique ECG data acquisition box with standard character keyboard streamlines the whole workflow. Waterproof and alphanumeric keyboard with backlight silicone shortcut keys for easy operation.Icon buttons on the screen for intuitive operation.♥ VCG ACQUISITION FOR MORE ADVANCED DIAGNOSIS:Vectorcardiogram (VCG), a kind of cardiogram for observing and recording the 3D electrical activities of human hearts, is commonly used for diagnosis and location for myocardial infarction, especially for posterior and inferior myocardial infarction. It can accurately record every moment of vector value, direction and process of changing. When the ECG diagnosis is uncertain, a VCG test may help.♥ 12-LEAD ECG WITH AUTHORIZED INTERPRETATION:Specific age and gender differential validity in Biocare's CardioPro™ ECG analysis program maximize the accuracy of the ECG interpretation. The analysis program has been proven by official CSE (Common Standards for Quantitative Electrocardiography) database evaluation with high accuracy and reliability in measurement and interpretation.♥ Detailed Measurement Data For Clinical Reference:The time-coherent data in multiple leads is stated on the ECG detailed report, creating a complete picture of a patient's heart rhythm. These measurements such as P-wave amplitude, R duration, and S-T segment data are listed clearly for clinical reference, which can help enhance the efficiency of diagnostic interpretation.♥ EASY ECG MANAGEMENT SYSTEM IN HOSPITALS:Interoperability can be gained with the help of ECG Management Systems. Physicians can also securely manage patient records within the hospital network. PRODUCT:Digital Electrocardiograph (Model: iE12A) WEIGHT (MAIN UNIT):7.5lbs / 3.4kg DEVICE DIMENSIONS:13.6" × 10.2" × 5.1"(345 mm × 260 mm × 128.5 mm) SCREEN:8.9'' TFT LCD full-view display FREQUENCY RESPONSE:0.05 Hz~250 Hz COMMON MODE REJECTION:>110dB (AC filter on);>100dB (AC filter off) DC POWER SUPPLY:Rechargeable built-in lithium battery (14.8V/ 4400mAh), support 3-hour operation INPUT:Touch screen, Standard full keyboard, Shortcut key, Support external scanner DATA STORAGE:≥3500 ECG files (when the ECG acquisition time is 10 seconds ), support external SD card、U disk Data Format:Data format ECG, XML, JPEG, DICOM, PDF LEAD Mode:Standard 12-lead, Nehb, Cabrera, Frank RHYTHM TIME:Record for a long term (30 s~300 s) and rhythm analysis PATIENT TYPE:Adults & Pediatrics ACQUISITION MODE:Simultaneous 12-lead Acquisition MEASUREMENT PARAMETERS: Standard leads: HR, PR interval, QRS duration, QT/QTC interval, P/QRS/T axis, RV5/SV1 voltage and RV5+SV1 voltage; Nehb lead: HR, PR interval, P duration, T duration, QRS duration, QT/QTC interval, P/QRS/T axis, P amplitude INPUT CIR CURRENT:≤0.1 μA PATIENT LEAK CURRENT: