Warning: Undefined array key "site" in /www/wwwroot/goods.9u.cl/app/Views/partials/header.php on line 66

Deprecated: explode(): Passing null to parameter #2 ($string) of type string is deprecated in /www/wwwroot/goods.9u.cl/app/Views/partials/header.php on line 66

Warning: Undefined array key 1 in /www/wwwroot/goods.9u.cl/app/Views/partials/header.php on line 68

Deprecated: strtoupper(): Passing null to parameter #1 ($string) of type string is deprecated in /www/wwwroot/goods.9u.cl/app/Views/partials/header.php on line 68
All returns accepted ReturnsNotAccepted
Brand System Sensor
Model System Sensor
MPN Does Not Apply

Check the listing for details. INNOVAIR-System Sensor Innovair D4120, 4-wire P/E Low-Flow Duct Smoke Detector. Condition: New. Listed at 200.00 USD. BRAND NEW AT FACTORY PACKAGE BOX Manufacturer:System SensorManufacturer Part#:D4120 FeaturesPhotoelectric, integrated low-flow technologyAir velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 m/sec)Versatile mounting options in square or rectangular configuration with modular constructionPlug-in sensor offers superb false alarm immunity with the latest sensor technologyIncreased wiring space with a newly added 3/4-inch conduit knock outBroad range for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing)Patented sampling tube installs from front or back of the detector with no tools requiredOne easy-access Test/Reset button and improved LED statusPatented interconnect feature for multi-fan shutdownNew high contrast terminal designationsBuilt-in short circuit protection from operator wiring errorsField selectable settings for configuring the detectorTwo DPDT Form-C relay contacts24 VAC/DC or 120VACBackward compatibility with existing Innovair products, including remote accessoriesDescriptionThe InnovairFlex D4120 4-wire photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. This unit senses smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of 4°F to 158°F, and a humidity range of 0 to 95 percent (noncondensing). A plug-in sensor head offers improved false alarm immunity and simple installation, testing, and maintenance. An improved cover design isolates the sensor head from the low-flow feature for simple maintenance.The InnovairFlex™ Series are the only duct smoke detectors flexible enough to fit configurations from square to rectangular and everything in between.The InnovairFlex housing provides ample wiring space, a 3/4-inch conduit knockout, and built-in short circuit protection to prevent damage to sensitive components during installation. High contrast terminal designations make wiring easy. With its 2:1 sensor-to-power capability, the power board of the D4120 may be used to monitor a second sensor ,D4S, simultaneously (i.e., supply and return side). As many as 50 InnovairFlex detectors can be interconnected. When one unit senses smoke, all interconnected detectors will switch their relays; only the detector sensing smoke will go into alarm, thus pinpointing the fire source.An easy-access Test/Reset button makes it possible to test the unit with the cover on. Three DIP switches can be used to configure field selectable settings: cover tamper delay, number of sensors to be controlled, and shut down on trouble option. Each power board has two LEDs that can be used to indicate the status of connected sensors, and a quick reference imprinted on the cover explains the LED status indications (Standby, Maintenance, Trouble, and Alarm). The InnovairFlex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new InnovairFlex product line is compatible with all previous Innovair models, including remote test accessories.WARNING: Duct smoke detectors have specific limitations.DUCT SMOKE DETECTORS ARE:NOT a substitute for an open area smoke detector,NOT a substitute for early warning detection, andNOT a replacement for a buildings regular fire detection system.Refer to NFPA 72 and 90A for additional duct smoke detector application information.Physical Specifications

$100.00
$200.00