| Restocking Fee | No |
|---|---|
| Return shipping will be paid by | Buyer |
| All returns accepted | Returns Accepted |
| Item must be returned within | 30 Days |
| Refund will be given as | Money back or replacement (buyer's choice) |
| Brand | Kaelus |
| MPN | RTF-1000A |
| Model | RTF-1000A |
| Frequency Range | 698 - 960 MHz |
Check the listing for details. Kaelus RTF-1000A Ranger 800MHz PIM & RTF Device Module 4 iQA 700, 850, 900 & 901. Condition: Used. Listed at 995.00 USD. The Following Items Are Included: Kaelus RTF-1000A Ranger 800 MHz PIM & RTF Device (BC# 40389) Case BE SURE TO CHECK OUR EBAY STORE FOR OTHER ITEMS! This Item Has A Current Calibration! Kaelus RTF-1000A Ranger 800 MHz PIM & RTF Device ModuleWorks with the following Kaelus iQA PIM Analyzer Models: 700L, 700H, 850, 900, 901Frequency Range:698 - 960 MHz Working Condition: ExcellentCondition: RefurbishedCalibrated: YesWarranty: 1 YEAR WARRANTY Kaelus RTF-1000A Ranger Range To Fault (RTF) is an exciting new technology from Kaelus that enables operators to accurately measure the location of PIM and Return Loss faults in their RF infrastructure. Reflection data together with PIM data provides an unmatched level of clarity for identifying the location of faults in the RF path. The RTF system consists of an RTF Module, interconnecting cables and a “RTF Enabled” iQA series PIM test instrument. Customers can purchase a new “RTF Enabled” PIM test analyzer from Kaelus or upgrade their existing A or B-series iQA test equipment to support RTF measurements. Please contact your local Kaelus representative for additional information. PEAK RETURN LOSS When the RTF module is attached a low power Return Loss vs. distance measurement will be made prior to activating the high power PIM test tones. If the peak calculated Return Loss is greater than a user specified value a warning will be presented to the operator along with the distance to the failing location. The operator has the option at this point to either abort the test or continue with the PIM measurement. This safety feature has been added to help prevent accidental high power RF transmissions while the feed system is open for repairs. DISTANCE TO LARGEST PIM SOURCE With an RTF Module attached the iQA user software provides four different views the operator can use to analyze PIM faults at the cell site. The “Basic” view clearly identifies the distance and magnitude of the largest static PIM fault on the line. For fastest results, Kaelus recommends methodically eliminating the largest PIM fault and repeating until all static PIM sources have been removed. Once the static PIM sources are removed, the operator can proceed to dynamic PIM testing to certify that the PIM performance is stable and robust. PIM VS. DISTANCE With a single button push, the operator can switch to “PIM” view to see the relative magnitude of all PIM sources on the line. A marker function is provided allowing the user to jump from peak to peak displaying the magnitude and distance to each PIM fault. Kaelus’ RTF solution utilizes proprietary enhanced resolution algorithms that enable the user to resolve closely spaced PIM faults that a standard FFT analysis can not see. RETURN LOSS VS. DISTANCE With a second button push, the operator can switch to “RL” view to see Return Loss vs. distance. As with the PIM view, a marker function is provided to display the magnitude and distance of each Return Loss peak. PIM & RETURN LOSS OVERLAY “OVL” view overlays Return Loss vs. distance and PIM vs. distance on a single screen. The user can independently set markers for both PIM peaks and Return Loss peaks and measure the relative distance between faults. Electrically long devices such as filters or TMAs, and changes in velocity factor caused by jumper cables vs. feeders can reduce the absolute accuracy of individual distance calculations. Since these errors impact both the PIM and Return Loss calculations equally, the relative distance between faults is typically more accurate than the individual distance calculations. Using the relative distance of a PIM problem to a known Return Loss peak allows users to locate faults on the line with more precision than with PIM vs. distance alone. Features: Accurately identify the location of PIM and Return Loss faults in the RF path Simple to operate, highly intuitive touch screen user interface Overlay PIM and Return Loss vs. distance data for enhanced troubleshooting capability Quickly switch between different test modes without disconnecting the line under test Compatible with any “RTF Enabled” iQA series PIM test instrument from Kaelus Speeds site repairs by guiding operators to the location of PIM faults Factory upgrades available for existing A and B-series iQA test instruments Before PIM testing, the RTF Module performs a Return Loss safety check to warn the operator before transmitting high RF power into a poor match Specifications: Frequency 698 - 960 MHz RTF analysis modes Numeric: Distance to maximum PIM + PIM Magnitude Graphical: PIM vs. Distance, Return Loss vs. Distance, PIM + RL vs. Distance Return Loss Max Return Loss (from FFT analysis) is displayed on the iQA main PIM test screen when the RTF module is attached Residual PIM < -115dBm/-158dBc max (